A sequence of steerage Notes has been issued, each one of which enlarges upon and amplifies the actual standards of part of BS 7671:2001 (IEE Wiring laws, sixteenth Edition). every one of those publications is widely cross-referenced to the rules therefore offering handy and prepared entry. a few information Notes comprise info no longer integrated within the sixteenth variation yet which used to be incorporated in past variants of the IEE Wiring rules. all of the publications were up to date to align with BS 7671: 2001.

Show description

Read Online or Download Guidance Note 5: Protection Against Electric Shock (IEE Guidence Notes) (No. 5) PDF

Similar construction books

Crossing boundaries, building bridges: comparing the history of women engineers, 1870s-1990s

Ladies engineers were within the public limelight for many years, but we've strangely little traditionally grounded knowing of the styles of employment and schooling of girls during this box. so much reports are both coverage papers or restricted to statistical analyses. additionally, the scant old learn to this point to be had emphasizes the person, unmarried and specified personality of these girls operating in engineering, frequently utilizing anecdotal proof yet ignoring better concerns just like the styles of the labour marketplace and academic associations.

The Construction of Cognitive Maps

And techniques that are particular to people of their encoding, storing, interpreting and retrieving spatial wisdom for numerous initiatives. The authors current and talk about connectionist types of cognitive maps that are in response to neighborhood illustration, as opposed to versions that are in line with disbursed illustration, in addition to connectionist versions relating language and spatial relatives.

Architect's Handbook of Construction Detailing, Second Edition

Considerably up-to-date with revisions to almost all 200-plus info, this moment variation of Architect's instruction manual of development Detailing offers architects, engineers, inside designers, contractors, and different development pros with all the universal building info, fabrics info, and detailing strategies used during the undefined.

Additional info for Guidance Note 5: Protection Against Electric Shock (IEE Guidence Notes) (No. 5)

Sample text

2. 2 Final circuits having 'mixed' disconnection times (Regulation 413-02-13) 413-02-13 distribution board circuit A L exposed-conductive-part fixed Load B circuit B load A (indoors) 230 V Uf N main earthing terminal If E protective conductor in cord Rc main equipotential bonding conductor further equipotential bonding conductor (if necessary) extraneous-conductive-part earth CD GN5 Protection Against Electric Shock, inc 16th Edition 2001 Amd No 1 37 Both circuits are fitted with fuse devices for protection against overcurrent and indirect contact.

3 SELV SELV (separated extra-low voltage) is an ELV system which is electrically separated from earth and from other systems in such a way that a single fault cannot give rise to the risk of electric shock. It should be appreciated that if a single fault were to occur it is intended that this should be confined to the SELV system and not involve any conductive parts of another system. Thus, the construction of a SELV system necessitates the use of high-integrity equipment and materials. g. a battery or an engine-driven generator, and if there is no other electrical system in the vicinity, the precautions to be taken relate only to the ELV system itself.

471-16 The primary circuit to a 415/110 V or 240/110 V portable transformer unit when used outdoors must be RCD protected to comply with the above-mentioned requirement. 7 Automatic disconnection and alternative supplies An important aspect of providing protection against indirect contact which can be readily overlooked by the designer is the need to ensure satisfactory operation of the relevant protective device(s) when the installation, or part thereof, is energised from a second source. This may be an alternative LV feed, a standby generator supply or an uninterruptible power supply (ups).